EconPapers    
Economics at your fingertips  
 

Validation of a finite element model with six-year-old child anatomical characteristics as specified in Euro NCAP Pedestrian Human Model Certification (TB024)

Haiyan Li, Kun Li, Yongqiang Huang, Wenle Lv, Shihai Cui, Lijuan He, Jesse Shijie Ruan and Chunxiang Wang

Computer Methods in Biomechanics and Biomedical Engineering, 2021, vol. 24, issue 1, 76-90

Abstract: Accident statistics show that more than 80% of car-to-pedestrian collisions (CPC) occur when pedestrians cross the road. It is very important to establish a finite element model with natural walking posture to study the kinematics and injury mechanism of pedestrians. In this study, a finite element model of six-year-old child pedestrian is developed with detailed anatomical characteristics and posture parameters as specified in Euro NCAP Pedestrian Human Model Certification (TB024). The numerical human body model is validated in total twelve simulations in which the pedestrian is impacted against four generic vehicle models at speeds 30, 40, 50 km/h prescribed in TB024. The Head Impact Time (HIT), Contact Force and the Trajectories of HC, T12 and AC of all twelve simulations are compared with the reference corridors provided by Technical Bulletin 024. The results indicate that the numerical human body model of a six-year-old child can be used to demonstrate the suitability of the sensing system for the range of pedestrian sizes; the timing of system deployment, and the bonnet deflection due to body loading. Furthermore, the model could be a good tool for further research on pedestrian injury mechanism and the development of pedestrian protection devices.

Date: 2021
References: Add references at CitEc
Citations:

Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2020.1810677 (text/html)
Access to full text is restricted to subscribers.

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:24:y:2021:i:1:p:76-90

Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20

DOI: 10.1080/10255842.2020.1810677

Access Statistics for this article

Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton

More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().

 
Page updated 2025-03-20
Handle: RePEc:taf:gcmbxx:v:24:y:2021:i:1:p:76-90