EconPapers    
Economics at your fingertips  
 

Effect of umbilical cord length on early fetal biomechanics

Juan Felipe Sánchez Gutiérrez, Mercedes Olaya-C, Jorge Andrés Franco, Johana Guevara, Diego Alexander Garzón-Alvarado and María Lucía Gutiérrez Gómez

Computer Methods in Biomechanics and Biomedical Engineering, 2021, vol. 24, issue 1, 91-100

Abstract: The umbilical cord suspends the fetus within the amniotic cavity, where fetal dynamics is one of its many functions. Hence, the umbilical cord is a viable index in determining fetal activity. Fetal movements result in mechanical loads that are fundamental for fetal growth. At present, mechanical environment during early human fetal development is still largely unknown. To determine early fetal movement dynamics at given physiological (0.060 m) and pathological umbilical cord lengths (0.030 m, 0.020 m, 0.017 m and 0.014 m) a 2D computational model was created to simulate dynamic movement conditions. Main findings of this computational model revealed the shortest umbilical cord length (0.014 m) with a 6(10−6)N, twitch force amplitude had a two-fold increase on linear velocity (0.12 m/s) in comparison with other lengths (0.05m/s). Moreover, umbilical cord length effect presented an increasing exponential tension on the fetus body wall from longest to shortest, from 0 N in the control length to 0.05 N for the shortest umbilical cord. Last, tension was always present over a period of time for the shortest cord (0.03 N to 0.08 N). Collectively, for all variables evaluated the shortest umbilical cord (0.014 m) presented remarkable differences with other lengths in particular with the second shortest umbilical cord (0.017 m), suggesting a 0.003 m difference represents a greater biomechanical effect. In conclusion, this computational model brings new insights required by clinicians, where the magnitude of these loads could be associated with different pathologies found in the clinic.

Date: 2021
References: Add references at CitEc
Citations:

Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2020.1811980 (text/html)
Access to full text is restricted to subscribers.

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:24:y:2021:i:1:p:91-100

Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20

DOI: 10.1080/10255842.2020.1811980

Access Statistics for this article

Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton

More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().

 
Page updated 2025-03-20
Handle: RePEc:taf:gcmbxx:v:24:y:2021:i:1:p:91-100