EconPapers    
Economics at your fingertips  
 

Design and fluid flow simulation of modified laparoscopic forceps

Md. Abdul Raheem Junaidi, Ram Chandra Murthy Kalluri, Y. V. Daseswara Rao, Alla Gopala Krishna Gokhale and Aakrit Patel

Computer Methods in Biomechanics and Biomedical Engineering, 2021, vol. 24, issue 8, 844-863

Abstract: Laparoscopic surgery has gained prominence in recent decades and employed in minimally invasive surgeries to avoid massive cuts resulting in a reduction in pain, the chance of infection, and duration of stay in the hospital. Maryland forceps, which belongs to the category of grasper instruments, are often used in minimally invasive surgeries to hold, pull, push, manipulate, and perform dissection operations. During laparoscopic surgeries, often blood and other body fluids ooze from the site of surgery. Typically, suction–irrigation (SI) devices are used to periodically clear these fluids to get a better view of the site of surgery. To achieve this, the removal and insertion of multiple instruments are required. This process has to be repeated numerous times, which significantly increases the time needed for surgery. Literature survey and feedback from practicing surgeons suggest that this can be avoided by improving the current design of forceps. In this article, a modified design is proposed by combining the SI feature with the existing form of Maryland forceps. The modified design is first modeled in SolidWorks and then analyzed for fluid flow using ANSYS Fluent. Parametric analysis is performed to obtain the optimal design for the proposed multi-functional instrument, which can potentially improve the overall efficiency of the laparoscopic surgical process.

Date: 2021
References: Add references at CitEc
Citations:

Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2020.1855331 (text/html)
Access to full text is restricted to subscribers.

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:24:y:2021:i:8:p:844-863

Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20

DOI: 10.1080/10255842.2020.1855331

Access Statistics for this article

Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton

More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().

 
Page updated 2025-03-20
Handle: RePEc:taf:gcmbxx:v:24:y:2021:i:8:p:844-863