In-silico investigation of airflow and micro-particle deposition in human nasal airway pre- and post-virtual transnasal sphenoidotomy surgery
Khashayar Moshksayan,
Hojat Bahmanzadeh,
Mohammad Faramarzi,
Sasan Sadrizadeh,
Goodarz Ahmadi and
Omid Abouali
Computer Methods in Biomechanics and Biomedical Engineering, 2022, vol. 25, issue 9, 1000-1014
Abstract:
Sphenoid sinus, located posterior to the nasal cavity, is difficult to reach for a surgery. Several operation procedures are available for sphenoidotomy, including endoscopic surgeries. Although the endoscopic sinus surgery is minimally invasive with low post-operative side effects, further optimization is required. Transnasal sphenoidotomy is a low invasive alternative to transethmoidal sphenoidotomy, but it still needs to be studied to understand its effects on the airflow pattern and the particle deposition. In this work, we simulated airflow and the micro-particle deposition in the nasal airway of a middle-aged man to investigate the change in particle deposition in the sphenoid sinus after virtual transnasal sphenoidotomy surgery. The results demonstrated that after transnasal sphenoidotomy, particle deposition in the targeted sphenoid sinus was an order of magnitude lower than that observed after virtual transethmoidal sphenoidotomy surgery. In addition, the diameter of the particles for the peak deposition fraction in the targeted sinus was shifted to smaller diameters after the transnasal sphenoidotomy surgery compared with that in the post-transethmoidal condition. These results suggest that the endoscopic transnasal sphenoidotomy can be a better procedure for sphenoid surgeries as it decreases the chance of bacterial contaminations and consequently lowers the surgical side effects and recovery time.
Date: 2022
References: Add references at CitEc
Citations:
Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2021.1995720 (text/html)
Access to full text is restricted to subscribers.
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:25:y:2022:i:9:p:1000-1014
Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20
DOI: 10.1080/10255842.2021.1995720
Access Statistics for this article
Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton
More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().