Topology optimization and dynamic characteristic evaluation of W-shaped interspinous process device
Li-Xin Guo and
Juan Liu
Computer Methods in Biomechanics and Biomedical Engineering, 2023, vol. 26, issue 13, 1610-1619
Abstract:
For reducing the adjacent segment degeneration of the lumbar spine, the interspinous process device as a kind of flexible non-fusion device was designed to overcome the deficiencies associated with rigid fusion devices. However, it was not clear how the interspinous process device influenced the human spine system, especially the lumbar spine under a vibration environment. This study was designed to evaluate the effect of StenoFix under the vibration condition and also to optimize the structure of the device to obtain better biomechanical performance. A finite element model of the intact lumbar spine was developed and validated. The surgical finite element model was constructed by implanting the interspinous process device StenoFix. Using topology optimization, a new device StenoFix-new was redesigned. The results showed that the interspinous process device decreased vibration amplitudes of annulus stress and intradiscal pressure under vibration at the surgical level. The redesigned StenoFix-new with the smaller stiffness exhibited a better dynamic flexibility performance than StenoFix. In addition, the range of motions of StenoFix-new was closer to the intact model than StenoFix at the surgical level. These results might encourage the designers to give more consideration to the dynamic characteristics of the human spine on the premise of ensuring the safety and strength of implanted devices.
Date: 2023
References: Add references at CitEc
Citations:
Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2022.2129968 (text/html)
Access to full text is restricted to subscribers.
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:26:y:2023:i:13:p:1610-1619
Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20
DOI: 10.1080/10255842.2022.2129968
Access Statistics for this article
Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton
More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().