EconPapers    
Economics at your fingertips  
 

Study on circumpelvic muscle deformation and dynamic simulation of pelvic fracture reduction

Jingtao Lei, Yanan Li and Haifei Xu

Computer Methods in Biomechanics and Biomedical Engineering, 2023, vol. 26, issue 6, 734-743

Abstract: For the pelvic fracture reduction, generally the fragment of the unaffected side is fixed and the affected side is moved to its correct anatomical position and orientation. During the pelvic fracture reduction, circumpelvic muscles deformation is closely related to the surgical accuracy. In this article, the biomechanical properties of musculoskeletal tissue during pelvic fracture reduction are studied. Five-parameter hyperelastic model named Mooney-Rivlin is adopted to analyze muscle’s stress–strain relationship. The finite element model of the injured pelvic musculoskeletal tissue is established, and the deformation of circumpelvic main muscles is simulated. Then, the dynamic simulation of pelvic fracture reduction is performed according to the planned spatial reduction path. The results show that when the muscles are stretched the same stretch length, the strain of the gluteus medius is the largest. It is most prone to deformation under and the muscle injury is most easily to occur. During the pelvic fracture reduction, the strain of gluteus maximus is the largest, and it is most prone to deformation and injury. The traction length is the largest, and the traction force mainly comes from the gluteus maximus. This study provides reference for the robot assisted pelvic fracture reduction.

Date: 2023
References: Add references at CitEc
Citations:

Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2022.2085999 (text/html)
Access to full text is restricted to subscribers.

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:26:y:2023:i:6:p:734-743

Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20

DOI: 10.1080/10255842.2022.2085999

Access Statistics for this article

Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton

More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().

 
Page updated 2025-03-20
Handle: RePEc:taf:gcmbxx:v:26:y:2023:i:6:p:734-743