Abstract:
The aim of this study was to evaluate the stress induced by clamps made of different materials on mandibular first molar teeth using finite element analysis. The tooth model to be used in the study was created using micro-CT scanner and the rubber dam clamp model was created in three dimensions (3D) using Solidworks and applied to a finite element tooth model of an intact mandibular first molar. The size of the clamp opening and the force to be applied were calculated according to the buccolingual distances of the tooth. The contact areas of the clamps on the tooth were determined and subjected to force. The stress distribution patterns and maximum von Mises stresses were calculated and compared against these forces. The most stress against these forces occurred in the enamel tissue on the distal side where the clamp was in contact with the tooth. The stress value in the stainless steel clamp (191.63 MPa) was approximately 85% higher than the clamp made of polyethylene ketone (103.85 MPa). The stress in the dentin and pulp tissue of the tooth was negligible. Clinicians should examine the enamel tissue below the equatorial line of the tooth in detail before clamp application. The forces exerted by stainless steel clamps can cause damage to the enamel tissue of the tooth or progression of an existing enamel crack.
Date: 2024
References: Add references at CitEc
Citations:
Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2023.2254882 (text/html)
Access to full text is restricted to subscribers.
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:27:y:2024:i:12:p:1704-1713
Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20
DOI: 10.1080/10255842.2023.2254882
Access Statistics for this article
Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton
More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().