Laboratory and field assessment of the capacitance sensors Decagon 10HS and 5TE for estimating the water content of irrigated soils

Fernando Visconti, José Miguel de Paz, Delfina Martínez and Mª José Molina

Agricultural Water Management, 2014, vol. 132, issue C, 111-119

Abstract: Capacitance sensors such as Decagon 10HS and 5TE are increasingly used for soil water content (θ) estimation. However, their reliability and limitations in clayey soils irrigated with saline waters have not been completely characterized under field conditions. Four levels of soil water content were combined with six levels of soil salinity in twenty-four pots to assess the performance of both sensors in a wide range of soil salinities. A simplified power-law dielectric mixing model was calibrated in the laboratory to estimate the θ of a clay loam soil from the measurements of apparent dielectric permittivity (ɛb) performed with both sensors. The calibrated equation was subsequently validated for the estimation of θ at two depths in six irrigated salt-threatened soils with clayey textures in SE Spain. The 10HS sensor provides higher estimations of ɛb than the 5TE. Besides, the 5TE sensor was more sensitive to soil salinity. Consequently, a different calibration was carried out for each sensor. When all the soil salinity treatments were included in the calibrations, the results were poor. However, for soil apparent electrical conductivities below 1.7dSm−1 the 5TE sensor could be calibrated with low prediction errors, and with the calibration parameters b0 and b1 very close to their characteristic values in clayey and mineral soils. In field testing, the 5TE sensors calibrated with the obtained equation provided average correct estimations with an error of ±0.05m3m−3. On the contrary, the 10HS sensor overestimated the soil water content by 0.07m3m−3 on average. The proposed simple calibration equation for the 5TE sensor can be reliably used under field conditions to estimate θ of irrigated clayey soils up to an apparent electrical conductivity of 1.7dSm−1.

Keywords: Irrigated clayey soils; Dielectric permittivity measurements; Electrical conductivity; Model calibration; Field validation; SE Spain (search for similar items in EconPapers)
Date: 2014
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (5)

Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0378377413002758
Full text for ScienceDirect subscribers only

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:eee:agiwat:v:132:y:2014:i:c:p:111-119

DOI: 10.1016/j.agwat.2013.10.005

Access Statistics for this article

Agricultural Water Management is currently edited by B.E. Clothier, W. Dierickx, J. Oster and D. Wichelns

More articles in Agricultural Water Management from Elsevier
Bibliographic data for series maintained by Catherine Liu ().

 
Page updated 2025-03-19