Optimization Design of Spray Cooling Fan Based on CFD Simulation and Field Experiment for Horticultural Crops
Yongguang Hu,
Yongkang Chen,
Wuzhe Wei,
Zhiyuan Hu and
Pingping Li
Additional contact information
Yongguang Hu: Key Laboratory of Modern Agricultural Equipment and Technology, Ministry of Education and Jiangsu Province, School of Agricultural Engineering, Jiangsu University, Zhenjiang 212013, China
Yongkang Chen: Institute of Field Management Equipment, School of Agricultural Engineering, Jiangsu University, Zhenjiang 212013, China
Wuzhe Wei: Institute of Field Management Equipment, School of Agricultural Engineering, Jiangsu University, Zhenjiang 212013, China
Zhiyuan Hu: Institute of Field Management Equipment, School of Agricultural Engineering, Jiangsu University, Zhenjiang 212013, China
Pingping Li: College of Biology and the Environment, Nanjing Forestry University, Nanjing 210037, China
Agriculture, 2021, vol. 11, issue 6, 1-18
Abstract:
In recent years, horticultural plants have frequently suffered significant heat damage due to excessive temperatures. In this study, a horticultural spray cooling system was designed, consisting mainly of a jet fan and spraying system. CFD simulation technology and response surface methodology were used to optimize the design of the jet fan, which improved the thrust of the fan. The length of the inlet section was 300 mm, the length of the outlet section was 300 mm, the length of the cone section was 450 mm, and the diameter of the outlet was 950 mm, where the thrust of the jet fan was 225.06 N. By establishing the CFD model of spray cooling in a tea field and designing a L 9 (3 4 ) orthogonal experiment, the effect of the spray parameters on the maximum temperature drop and effective cooling distance was studied, and the best parameters were selected. The simulation results show that the optimum parameters are a spray flow rate of 4.5 kg/s, a droplet diameter of 15–45 ?m, a droplet temperature of 298.15 K, and a nozzle double circle layout. Based on the simulation results of the optimized jet fan and spray parameters selected, a spray cooling test bench was established. Field test results show that when the initial ambient temperature was 310.05 K–310.95 K, the maximum temperature drop of the spray cooling fan was 9.1 K, and the cooling distance was approximately 36.0 m. The temperature drop decreased with increasing distance from the fan. This study is of great significance to protect horticultural plants from extremely high temperatures.
Keywords: spray cooling; CFD technology; jet fan; cooling effect (search for similar items in EconPapers)
JEL-codes: Q1 Q10 Q11 Q12 Q13 Q14 Q15 Q16 Q17 Q18 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/2077-0472/11/6/566/pdf (application/pdf)
https://www.mdpi.com/2077-0472/11/6/566/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jagris:v:11:y:2021:i:6:p:566-:d:578462
Access Statistics for this article
Agriculture is currently edited by Ms. Leda Xuan
More articles in Agriculture from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().