EconPapers    
Economics at your fingertips  
 

Experimental results of transcritical CO2 heat pump for residential application

M.R. Richter, S.M. Song, J.M. Yin, M.H. Kim, C.W. Bullard and P.S. Hrnjak

Energy, 2003, vol. 28, issue 10, 1005-1019

Abstract: This paper describes experiments comparing a commercially available R410A heat pump and prototype R744 (carbon dioxide) system in heating mode. The R744 system utilizes aluminum microchannel heat exchangers and a prototype semi-hermetic compressor. System performance is compared for two configurations: first, when the R744 compressor speed is set to match the baseline system’s heating capacity at 8.2 °C outdoors and 21.1 °C indoors; and second, when the air conditioning capacity is matched at 35 °C outdoors and 26.5 °C indoors. The R744 system operates with a slightly lower heating COP, but its higher capacity at lower outdoor temperatures reduces the need for less efficient supplementary heating capacity.

Date: 2003
References: View complete reference list from CitEc
Citations: View citations in EconPapers (11)

Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0360544203000653
Full text for ScienceDirect subscribers only

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:eee:energy:v:28:y:2003:i:10:p:1005-1019

DOI: 10.1016/S0360-5442(03)00065-3

Access Statistics for this article

Energy is currently edited by Henrik Lund and Mark J. Kaiser

More articles in Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().

 
Page updated 2025-03-19
Handle: RePEc:eee:energy:v:28:y:2003:i:10:p:1005-1019