A double-step Savonius rotor for local production of electricity: a design study
J.-L. Menet
Renewable Energy, 2004, vol. 29, issue 11, 1843-1862
Abstract:
This paper presents a study, carried out with the help of the French Agency of Innovation (ANVAR). It deals with the conception of a small Savonius rotor (i.e. of low power) for local production of electricity. Our challenge was to design, develop and ultimately build a prototype of such a rotor, which was considered as a complete electromechanical system. An optimised configuration was chosen for the geometry of the present prototype. The building data were calculated on the basis of the nominal wind velocity V=10 m/s. Particular care was necessary to choose the appropriate generator, which was finally a rewound conventional car alternator. The whole design of the prototype has confirmed the high efficiency and the low technicality of the Savonius rotors for local production of electricity. The present prototype is to be tested in situ.
Keywords: Savonius rotor; Wind turbine; Vertical axis; Electricity; Design (search for similar items in EconPapers)
Date: 2004
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (34)
Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0960148104000916
Full text for ScienceDirect subscribers only
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:eee:renene:v:29:y:2004:i:11:p:1843-1862
DOI: 10.1016/j.renene.2004.02.011
Access Statistics for this article
Renewable Energy is currently edited by Soteris A. Kalogirou and Paul Christodoulides
More articles in Renewable Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().