EconPapers    
Economics at your fingertips  
 

Multi-scale finite element modelling at the posterior lumbar vertebra: analysis of pedicle stresses due to pars fracture

Serkan İnceoğlu and Prasath Mageswaran

Computer Methods in Biomechanics and Biomedical Engineering, 2014, vol. 17, issue 7, 787-791

Abstract: Multi-scale finite element (FE) model is a cost-effective way to analyse stress response of micro-level structures to the changes in loading at macro-level. This study deals with the development of a multi-scale model of a human vertebra and stress changes in the pedicle at high resolution after a gross fracture at the posterior neural arch. Spondylolysis (pars fracture) is a painful condition occurring in the vertebral neural arch and common especially among the athletic young population. The fracture of the pars significantly alters load distribution and load transfer characteristics at the neural arch. Structural changes in the posterior vertebra due to the new loading patterns can trigger secondary complications. Clinical reports have shown the association of pedicle hypertrophy or pedicle fracture with unilateral pars fractures. However, the biomechanical consequences of pars fracture and its effect on the pedicle have never been studied in detail. Therefore, we prepared a multi-scale model of posterior vertebra with continuum laminar complex model combined with micro-FE model of a pedicle section. The results showed that stress at the contralateral pars and pedicle increased after unilateral pars fracture simulation. High-stress regions were found around the outer boundaries of the pedicle. This model and information are helpful in understanding the stress changes in the pedicle and can be used for adaptive remodelling studies.

Date: 2014
References: Add references at CitEc
Citations:

Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2012.716046 (text/html)
Access to full text is restricted to subscribers.

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:17:y:2014:i:7:p:787-791

Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20

DOI: 10.1080/10255842.2012.716046

Access Statistics for this article

Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton

More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().

 
Page updated 2025-03-20
Handle: RePEc:taf:gcmbxx:v:17:y:2014:i:7:p:787-791