EconPapers    
Economics at your fingertips  
 

Evaluation of liver tissue damage and grasp stability using finite element analysis

Lei Cheng and Blake Hannaford

Computer Methods in Biomechanics and Biomedical Engineering, 2016, vol. 19, issue 1, 31-40

Abstract: Minimizing tissue damage and maintaining grasp stability are essential considerations in surgical grasper design. Most past and current research analyzing graspers used for tissue manipulation in minimally invasive surgery is based on in vitro experiments. Most previous work assessed tissue injury and grasp security by visual inspection; only a few studies have quantified it. The goal of the present work is to develop a methodology with which to compute tissue damage magnitude and grasp quality that is appropriate for a wide range of grasper–tissue interaction. Using finite element analysis (FEA), four graspers with varying radii of curvature and four graspers with different tooth sizes were analyzed while squeezing and pulling liver tissue. All graspers were treated as surgical steel with linear elastic material properties. Nonlinear material properties of tissue used in the FEA as well as damage evaluation were derived from previously reported in vivo experiments. Computed peak stress, integrated stress, and tissue damage were compared. Applied displacement is vertical and then horizontal to the tissue surface to represent grasp and retraction. A close examination of the contact status of each node within the grasper–tissue interaction surface was carried out to investigate grasp stability. The results indicate less tissue damage with increasing radius of curvature. A smooth wave pattern reduced tissue damage at the cost of inducing higher percentage of slipping area. This methodology may be useful for researchers to develop and test various designs of graspers. Also it could improve surgical simulator performance by reflecting more realistic tissue material properties and predicting tissue damage for the student.

Date: 2016
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2014.981166 (text/html)
Access to full text is restricted to subscribers.

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:19:y:2016:i:1:p:31-40

Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20

DOI: 10.1080/10255842.2014.981166

Access Statistics for this article

Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton

More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().

 
Page updated 2025-03-20
Handle: RePEc:taf:gcmbxx:v:19:y:2016:i:1:p:31-40