Contribution of injured posterior ligamentous complex and intervertebral disc on post-traumatic instability at the cervical spine
Marie-Hélène Beauséjour,
Yvan Petit,
Jeremy Hagen,
Pierre-Jean Arnoux,
Jean-Marc Mac Thiong and
Eric Wagnac
Computer Methods in Biomechanics and Biomedical Engineering, 2020, vol. 23, issue 12, 832-843
Abstract:
Posterior ligamentous complex (PLC) and intervertebral disc (IVD) injuries are common cervical spine flexion-distraction injuries, but the residual stability following their disruption is misknown. The objective of this study was to evaluate the effect of PLC and IVD disruption on post-traumatic cervical spine stability under low flexion moment (2 Nm) using a finite element (FE) model of C2-T1. The PLC was removed first and a progressive disc rupture (one third, two thirds and complete rupture) was modeled to simulate IVD disruption at C2-C3, C4-C5 and C6-C7. At each step, a non-traumatic flexion moment was applied and the change in stability was evaluated. PLC removal had little impact at C2-C3 but increased local range of motion (ROM) at the injured level by 77.2% and 190.7% at C4-C5 and C6-C7, respectively. Complete IVD rupture had the largest impact on C2-C3, increasing C2-C3 ROM by 181% and creating a large antero-posterior displacement of the C2-C3 segment. The FE analysis showed PLC and disc injuries create spinal instability. However, the PLC played a bigger role in the stability of the middle and lower cervical spine while the IVD was more important at the upper cervical spine. Stabilization appears important when managing patients with soft tissue injuries.
Date: 2020
References: Add references at CitEc
Citations:
Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2020.1767776 (text/html)
Access to full text is restricted to subscribers.
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:23:y:2020:i:12:p:832-843
Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20
DOI: 10.1080/10255842.2020.1767776
Access Statistics for this article
Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton
More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().