Development of a musculoskeletal model of the wrist to predict frictional work dissipated due to tendon gliding resistance in the carpal tunnel
J. D. Glenday,
B. Steinhilber,
F. Jung and
D. F. B. Haeufle
Computer Methods in Biomechanics and Biomedical Engineering, 2021, vol. 24, issue 9, 973-984
Abstract:
Carpal tunnel syndrome is an entrapment neuropathy that has been associated with the aggravation of tendon gliding resistance due to forceful, high velocity, awkwardly angled, and repetitive wrist motions. Cadaveric and epidemiological studies have shown that combinations of these risk factors have a more than additive effect. The aim of the current study was to develop a musculoskeletal model of the wrist that could evaluate these risk factors by simulating frictional work dissipated due to the gliding resistance of the third flexor digitorum superficialis tendon. Three flexion angle zones, three extension angle zones, five levels of task repetitiveness, and five levels of task effort were derived from ergonomic standards. Of the simulations performed by systematically combining these parameters, the extreme wrist flexion zone, at peak task repetitiveness and effort, dissipated the most frictional work. This zone dissipated approximately double the amount of frictional work compared to its equivalent zone in extension. For all motions, a multiplicative effect of the combination of task repetitiveness and effort on frictional work was identified by the musculoskeletal model, corroborating previous epidemiological and experimental studies. Overall, these results suggest that the ergonomic standards for wrist flexion-extension may need to be adjusted to reflect equivalent biomechanical impact and that workplace tasks should be designed to minimise exposure to combinations of highly repetitive and highly forceful work, especially when the wrist is highly flexed.
Date: 2021
References: Add references at CitEc
Citations:
Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2020.1862094 (text/html)
Access to full text is restricted to subscribers.
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:24:y:2021:i:9:p:973-984
Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20
DOI: 10.1080/10255842.2020.1862094
Access Statistics for this article
Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton
More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().