EconPapers    
Economics at your fingertips  
 

Influence of posterior cruciate ligament tension on tibiofemoral and patellofemoral joint contact mechanics in cruciate-retaining total knee replacement: a combined musculoskeletal multibody and finite-element simulation

Jan-Oliver Sass, Kurt Johnson, Jean-Baptiste Darques, Lucas Buerstenbinder, Iman Soodmand, Rainer Bader and Maeruan Kebbach

Computer Methods in Biomechanics and Biomedical Engineering, 2025, vol. 28, issue 10, 1577-1589

Abstract: The influence of posterior cruciate ligament (PCL) tension on the clinical outcome of cruciate-retaining total knee replacement (CR-TKR) remains controversial. Various numerical approaches have been used to study this influence systematically, but the models used are limited by certain assumptions and simplifications. Therefore, the objective of this computational study was to develop a combined musculoskeletal multibody and finite-element simulation during a squat motion to 90° knee flexion with a CR-TKR design to overcome previous limitations regarding model inputs. In addition, different PCL tensions (tight, lax, resected) were modeled and the influence on tibiofemoral and resurfaced patellofemoral joint dynamics and contact stresses was evaluated. The effect of the PCL on knee joint dynamics and contact stresses was more pronounced at higher flexion angles. Tibiofemoral joint dynamics were influenced and a tight PCL induced increased posterior femoral translation during flexion. The maximum contact stress in the tibial insert increased from 20.6 MPa to 22.5 MPa for the resected and tightest PCL at 90° knee flexion. Patellofemoral joint dynamics were only slightly affected by PCL tension. However, the maximum contact stress in the patellar component decreased from 58.0 MPa to 53.7 MPa for the resected and tightest PCL at 90° knee flexion. The combination of musculoskeletal multibody and finite-element simulation is a sufficient method to comprehensively investigate knee joint dynamics and contact stresses in CR-TKR. The PCL tension after CR-TKR affects joint dynamics and contact stresses at the articulating implant surfaces.

Date: 2025
References: Add references at CitEc
Citations:

Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2024.2329946 (text/html)
Access to full text is restricted to subscribers.

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:28:y:2025:i:10:p:1577-1589

Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20

DOI: 10.1080/10255842.2024.2329946

Access Statistics for this article

Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton

More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().

 
Page updated 2025-08-05
Handle: RePEc:taf:gcmbxx:v:28:y:2025:i:10:p:1577-1589