EconPapers    
Economics at your fingertips  
 

Hypopharyngeal geometry impact on air-induced loads on the supraglottis

L. Reid and M. Hayatdavoodi

Computer Methods in Biomechanics and Biomedical Engineering, 2025, vol. 28, issue 2, 254-264

Abstract: Exercise-induced laryngeal obstruction (EILO) describes paradoxical laryngeal closure during inspiration at high-intensity exercise. It is hypothesised that during intense activity, the air-induced loads on supraglottic walls overcome their internal stiffness, leading to the obstruction. Recent investigations have revealed that the air-induced loads on the supraglottic walls vary nonlinearly with increasing flow rate. It is, however, unclear whether certain geometric configurations of the hypopharynx and larynx may contribute to the predisposition to EILO. This study investigates the influence of hypopharyngeal and laryngeal geometry on upper respiratory tract airflow and air-induced forces. A computational fluid dynamics model is developed to study airflow through larynx. Four real, adult upper respiratory tracts with variable configurations are considered. Two steady, uniform inspiratory flow rates of 60 L/min and 180 L/min are considered. The analysis shows that geometries with a space lateral to the epiglottis (EpiS) and piriform fossae (PF) directs the hypopharyngeal and supraglottic pressure field to remain positive and increase with the flow rate. In geometries with EpiS and PF, pressure differential occurs around the aryepiglottic fold producing a net inward force over the region. The three-fold increase in flow rate induces near ten-fold increases in force over the region which may facilitate the closure. It is concluded that hypopharyngeal anatomy, particularly the piriform fossae, play a significant role in the obstruction of the supraglottic airway and should be considered in research and clinical assessment of EILO.

Date: 2025
References: Add references at CitEc
Citations:

Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2023.2285723 (text/html)
Access to full text is restricted to subscribers.

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:28:y:2025:i:2:p:254-264

Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20

DOI: 10.1080/10255842.2023.2285723

Access Statistics for this article

Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton

More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().

 
Page updated 2025-03-20
Handle: RePEc:taf:gcmbxx:v:28:y:2025:i:2:p:254-264