Effect of pre-stress on dynamic finite element analysis of the temporomandibular joint
Haidong Teng,
Jingheng Shu,
Hedi Ma,
Bingmei Shao and
Zhan Liu
Computer Methods in Biomechanics and Biomedical Engineering, 2025, vol. 28, issue 3, 353-363
Abstract:
The pre-stress of the temporomandibular joint (TMJ) at the intercuspal position (ICP) was often neglected, which would cause errors in the finite element analysis. The purpose of this study was to investigate the effect of pre-stress on dynamic finite element analysis of the TMJs. One healthy female adult was recruited for medical imaging and motion data acquisition of the reference position (RP) to the ICP and the clicking teeth. The three-dimensional maxillofacial model including the maxilla, mandible, articular cartilages, discs, and discal attachments was reconstructed. Motion from the RP to the ICP was simulated to obtain pre-stress at the ICP. Two groups of the clicking teeth were simulated: (1) the group without pre-stress (GWoP); (2) the group with pre-stress (GwP). Significant differences were found between the two groups at the initial moment of movement, during the open-mouth phase, and during the collision phase between the upper and lower teeth. The maximum difference in the discal contact stress between both groups was even more than double. The relaxation of the TMJ at the beginning of the mouth opening was simulated in the GwP. In addition, an increase in the TMJ stress during teeth tapping was simulated in the GwP. These were not reflected in the GWoP. If pre-stress at the ICP was not considered, part of the true results would be lost. It is necessary to consider pre-stress in the dynamic finite element analysis of the TMJ.
Date: 2025
References: Add references at CitEc
Citations:
Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2023.2290455 (text/html)
Access to full text is restricted to subscribers.
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:28:y:2025:i:3:p:353-363
Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20
DOI: 10.1080/10255842.2023.2290455
Access Statistics for this article
Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton
More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().